○ Programming controlled in the process of measurement(1-50remembered groups,1-9steps in each groups)
CHP-500Cadopts LCD display, use AC - DC - AC frequency conversion technology, digital waveform synthesis and wave form feed back technology, power distortion is low; The high precision, full period and the fastest sampling measurement technology, directly show output voltage, frequency, current, active power and power factor arerealized the power supply and meter all in one; High degree of intelligence; Isolation of the floating output technology, good isolation and floating output of the power output and input, it's good for self-safety and operation security of power supply; Perfect voltage, abnormal current and overheat protection to improve reliability of power supply.
> Power supply : AC 110V±10% or 220V±10% 50/60Hz
> Output frequency setting: 45.00~500.00Hz
> Phase set: 0°~359 (±1°)
> Output voltage setting: AC 0.0~300.0V
> Max allowable output current: 0~150V is 4.2A,0~300V is 2.1A
> Meter display
> Total voltage distortion: ≤0.3%(empty load or full resistance load)
> Voltage stability: ≤0.1%/30min
> Equivalent resistance: ≤0.1(zero inner resistance design)
> Load adjust rate: ≤0.1%
> Frequency stability: ≤0.05%/30min
1) Adopting AC-DC-AC frequency conversion technology, digital wave synthesis, wave feed-back technology with low power distortion
2) Adopting high speed sampling technology, exactly display voltage, frequency, current, power and power factor
3) Controlled and tested by SCM, which has high intelligentized grade
4) Adopting Zero output impedance technology. Not only make the output equivalent resistance approach zero, but also improve the stability of the power source
5) Insulation for power output to make test safely and steady
6) Protection for over heat and thundering voltage and current, improve the stability of the power
7)Adopting the limited-current technology, to prevent the high interference and be beneficial to work safely
8) 110 /220 V options for input voltage which can be selected by the switcher button on the rear panel
9) Initial phase and end phase of output voltage waveform can be set (0°~359°)
10) Programmed control of measurement process. 1 to 50 memory groups. 1-9 steps for each memory group
电话
0571-88262181邮箱
sales@inventfine.cn地址
No.11 LinGang Road, YuHang District,Hangzhou.扫码关注创惠