GPM-3000 Sportive Reflector Goniophotometer


产品性能

○ Fully meet IESNA LM-79 to Type C Goniophotometer
○ CIE T0 Recommended.

  • 产品介绍
  • 产品参数
  • 产品特征
  • 工作原理
  • 满足标准
  • 适用范围

    GPM-3000 Goniophotometer is a highly intelligent light distribution performance testing system.  It can measure all types of lighting source and luminaires.(Such as Indoor and Outdoor luminaires, Street luminaires, Flood lamps, etc) with high accuracy. It can achieve the test methods of CIE C-γ,  CIE B- β and CIE A-α.The tested results can be directly used by international lighting design software like Dialux. It meets and requirements of CIE and IESNA standards.

    GPM-3000 分布光度计.jpg


    report.jpg

    report-1.jpg

    File output format 

    *.CIE CIE

    *.IES IESNA 

    *.IDT EULUMDAT

    *.CIB CIEBSE

    *.TM4 CIEBSE

    *.CEN DIN

    *.CSV EXCEL


    >Tested light can rotate around the reflecting mirror (γ) ± 180 ° ( or 0-360°) rotation, the measured light itself can be rotated (C) ± 180 ° (or 0-360 °)

    >Angular precision:0.1 degree,  resolution of driving angle:0.01 degree

    >Photometric test range

       Luminance:0.01lx-10000lx    Intensity:1cd-107cd(detector)

    >Photometric test precision:2%(standard illuminants)

    >Stray light:≤ 0.1%

    >Maximum size lamps and lanterns which can be tested

       Diameter:1400mm           Weight:40Kg

    >Working power supply 

       1)Supply voltage:AC 220V±5% (export product is designed as the customer’s requirement)

       2)Power frequency:50Hz/60Hz

       3)Power consumption:static 180VA,dynamic 650VA

    >Working environment required

       1)Working environment temperature:0~35℃

       2)Ideal temperature in normal test:25±2℃

       3)Relative humidity:less than 70%(no condensation, air-condition is suggested to install)

    >Main engine size and weight

      1)Size:length x width x height(4800mm×3000mm×4750mm)

      2)Weight:2000Kg

    >The tested data must meet the requirements of international and national standards, IESNA file format output can transfer other lighting and lamps and lanterns design software

    >RS-485 standard interface, convenient to connect with various micro computer, standard English/Chinese operator interface, meets the international requirements

    >Tested lamp position and the actual use state are the same, lamps working condition is unchanged

    >Special laser cross line aiming device, be convenient and accurate to install the tested lamps and lanterns

    >Advanced commutater which adopts the precious metal optical fiber dot brushing technology, can achieve continuous test with the advantages of no winding, start and stop intelligently

       smooth rotation and low noise



    1) The mirror rotates around the tested luminaire with an angle of (γ)±180°(or 0~360°),and the tested luminaire rotates around itself with an angle of (C)±180°(or 0~360°).The detector 

        rotate with mirror synchronously or rotate around the tested luminaire (0-360° ) 

    2) Using high level redirector made up by special metal fiber, no winding, intelligent startup and stop , keep stable rotating, continuous testing  and low noise.

    3) The position and working state remain the same as it is under test. Laser cross line aiming device to ensure fixing the test lamps accurately and conveniently.

    4) The accuracy of angle :0.1° , resolution of angle :0.01°.

    5) The accuracy of  photometric:standard class.

    6) The tested data meets the international and national standard requirements.Test result can be output with IES,IDT,CEN, CIB,CSV.TM4,CIE files and directly used by design software like Dialux.


    GPM-3000分布光度计工作原理-1.jpg

    GPM-3000分布光度计工作原理.jpg

    CIE Pub. NO.70, “The Measurment of Absolute Luminous Intensity Distributions”

    CIE DIV.Ⅱ-TC10, “Photometry of Luminaires”

    CIE Pub.NO.76, “Photometry-the CIE Sytstem of Physical Photometry”

    CIE 121-1996 “The Photometry of Goniophotometer of Luminaries”

    IESNA LM-75 “Goniophotometer Types and Photometric Coordinates”

    IESNA LM-79 “Electrical and Photometric Measurements of Solid-state Lighting Products”

    IESNA-1971(73-96),“IES Practical Guide to Photometry”

    IESNA 61341 “Method of Measurement of Center Beam Intensity and Beam Angle(s) of Reflector Lamp”

    GB/T 9467-2008, “Photometric test of indoor lamps and lanterns”

    GB/T 9468-2008, “Photometric test of road lighting fixtures”

    GB/T 7002-2008,“Photometric test of flood lighting fixtures”

    LB/T 001-2008 “Measurement Method of Integral LED Street Lamp”

    GB/T 24824-2009 “Measurement Method of LED Module for General Lighting”

    LB/T 001-2009  “Measurement Method of Integral LED Street Lamp”

    ...

    Such as Indoor and Outdoor luminaires, Street luminaires, Flood lamps, etc