According to the CIE and IEC standard test method for LEDs, it is dedicated to the measurment of single and combination LED'S electrical performance, photometric performance, distribution of beam and other characteristic parameters .Equipped with test grating and test camera obscura,the instrument can meet testing requirements in any environment . It is mainly applied to all the parameters'measurement of single LED, reflected light, par LED etc.


Test interface

Test report
>Test range of luminosity: 0.1锝30,000lx
>Test accuracy of luminosity: Class 1
>Test range of angle: vertical axis锛90掳锝烇紜90掳; horizontal axis 0掳锝360掳
>Test accuracy of angle: 卤0.2掳
>Interval selection for testing angle: 0.5掳/1掳/1.5掳
>Draw spatial luminous intensity distributional curve automatically (polar coordinates and right-angle coordinates)
>Mensure beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4 intensity angle and 1/10 intensity angle which meets the special requirements.
>The size of tested lamp is 桅22锝炍180mm
>The distance between the tested lamp and detector is 316mm/1000mm
>Work power supply:
a) Power supply voltage: AC 220V卤10%
b) Power frequency: 50Hz/60Hz
c) Power dissipation: 35VA
>Requirement of working environment:
a) Allowable working environmental temperature: 0鈩冿綖40鈩
b) Best temperature for normal test: 25鈩兟5鈩
c) Relative humidity: 鈮65锛匯.H
>Test range of luminosity: 0.1锝30,000lx
>Test accuracy of luminosity: Class 1
>Test range of angle: vertical axis锛90掳锝烇紜90掳; horizontal axis 0掳锝360掳
>Test accuracy of angle: 卤0.2掳
>Interval selection for testing angle: 0.5掳/1掳/1.5掳
>Draw spatial luminous intensity distributional curve automatically (polar coordinates and right-angle coordinates)
>Mensure beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4 intensity angle and 1/10
intensity angle which meets the special requirements.
>The size of tested lamp is 桅22锝炍180mm
>The distance between the tested lamp and detector is 316mm/1000mm
>Work power supply:
a) Power supply voltage: AC 220V卤10%
b) Power frequency: 50Hz/60Hz
c) Power dissipation: 35VA
>Requirement of working environment:
a) Allowable working environmental temperature: 0鈩冿綖40鈩
b) Best temperature for normal test: 25鈩兟5鈩
c) Relative humidity: 鈮65锛匯.H

CIE Pub. NO.70, 鈥淭he Measurment of Absolute Luminous Intensity Distributions鈥
CIE DIV.鈪-TC10, 鈥淧hotometry of Luminaires鈥
CIE Pub.NO.76, 鈥淧hotometry-the CIE Sytstem of Physical Photometry鈥
CIE 121-1996 鈥淭he Photometry of Goniophotometer of Luminaries鈥
IESNA LM-75 鈥淕oniophotometer Types and Photometric Coordinates鈥
IESNA LM-79 鈥淓lectrical and Photometric Measurements of Solid-state Lighting Products鈥
IESNA-1971(73-96),鈥淚ES Practical Guide to Photometry鈥
IESNA 61341 鈥淢ethod of Measurement of Center Beam Intensity and Beam Angle(s) of Reflector Lamp鈥
...
Suitable for single LED, cob, small downlight, spotlight and par lamp